RW series,12kV/15kV Dropout fuse cutout

RW series,12kV/15kV Dropout fuse cutout
Product Detailed
1. Porcelain type fuse cutout 2, fuse cutout 3. Easy installation.

Fuse cutout

Drop-out fuse cutout and load switching fuse cutout are of outdoor used high voltage protective device,Tobe connected with incomin-g feeder of distribution transformer or distribution lines,it mainly protect transformer or lines from short circuit and overload,and on/off loading,current,Drop-out fuse cutout is composed of insulate insulator supports and fuse tube,static contacts is fixed on two sides of insulator support and moving contact is installed on two ends of fuse tube,Fuse tube is composed of inside arcexting tube.Outer phenolic compound paper tube or epoxy glasstube,Load switching fuse cutout provides enfored elastic auxiliry contacts and arc-extinguishing exclosure switching on-off loading current.At normally working via fuselink tightened the fuse tube is fixfed to form up of close position.In case system occure faults,fault current result result in fuse melt immediately and take piece electric are,which let arc-extinguishing tube being heated and fexplode a lot of gas,Th-os will produce high pressure and below of the are along with tube. After fuselink melt melt moving contact has no tightened strength again,mecganismis locked and fuse tube drop out, Cutout now is in open position,When it needs to switch off during cutout loading,operat-or shall via insulating operating bar pull the moving contact,atits beginning main contact and auxiliary static contactic contactedst-ill, Whiling pulling the auxiliary contact is separated between auxiliary contacts there occur electric arc and the arc will be lengthene-d in arc-extinguishing enclosure gap and meanwhile arc-exting explode gas to blow off the arc during current passing zero.

Detailed Specifications of Fuse Cutout:

 

 

RW series,12kV/15kV Dropout fuse cutout